Equipment Layout All equipment is divided into three zones: control zone, operating zone and power zone. Pipeline control components and electric control system are arranged together. Please check Fig. 2.1 for more details. Fig. 2.1 Layout Drawing of 700LX3 Supercritical Extraction Equipment Tags: 700LX3 Supercritical Extraction Equipment Layout Drawing, Supercritical CO2 Extraction Diy, CO2 Extraction […]
Month: May 2019
What’s the 700L*3 Supercritical CO2 Extraction Equipment Installation Parametersand Public Utilities?
700L*3 Supercritical CO2 Extraction Equipment Parameters for Installation Temperature: indoor 10~25℃; Altitude: ≤1100m; Floor Area: 352m2 (19.5m×18m, not including outdoor storage tank, cold water tower); Floor Area Needed for Outdoor Storage Tank: 31.9m2 (5.8m×5.5m); Floor Area Needed for Cold Water Tower: 33m2 (6m×5.5m); 700L*3 Supercritical CO2 Extraction Equipment Public Utilities Power: AC 380, three phases, […]
What’s the Supercritical CO2 Extraction Machine Safety Operating Instructions for Repair and Maintenance
Supercritical CO2 Extraction Machine Safety Operating Instructions for Repair and Maintenance a)Pressure vessels, pipelines and valves of the extraction equipment must be inspected and experimented periodically according to local regulations of the user. It’s only allowed to be put into use after its conformity with local regulations. b)Operating staff should take immediate measures to shut […]
What’s the CO2 Supercritical Extraction Safety Operation Requirements
CO2 Supercritical Extraction Safety Operation Requirements a)Before operation, operating staff should read Operating Manual for 700LX3 Supercritical Extraction Equipment carefully, and strictly follow it to control and operate the equipment. b)Operating staff should check lubricant oil and surface of the pumps and if their work environment is under safe condition. They should add lubricant oil […]
What’s the Supercritical CO2 Extraction Machine Requirements for Operating Staff
Supercritical CO2 Extraction Machine Requirements for Operating Staff a)Operating staff should pass the special equipment operating training and operate the equipment with a special equipment operating permission from local supervisory agency. b)Operating staff should be familiar with the equipment’s structure and performance, have a good knowledge of CO2’s physiochemical properties and the operating procedures of […]
Supercritical CO2 Extraction Workshop Operation Rules
Supercritical CO2 Extraction Workshop Operation Rules a)The environment should be clean and items tidy. Safe passage is clear without any obstacles. b)Good ventilation in the workshop should be guaranteed to avoid workers’ lack of oxygen led by high CO2 density. c)Chloride ion content in the water used in this system should not be more than […]