Operation of CO2 Tank C302 The CO2 storage tank C302 is a closed container. The magnetic flap level gauge outside the container can display the CO2 liquid level situation in real time. a) Operation steps when the tank is used for the first time 1) Open the CO2 inlet valve J09 on the top of […]
Author: tradematt
Operation of CO2 Transfer Pump P501-700L Supercritical Fluid Extraction
Operation of CO2 Transfer Pump P501 a) Name explanation: 1) First switch on: It means that the pump starts for the first time after it stops working for a long time; 2) Normal switch on: means the pump starts again after a short stop; b) Operation steps: The CO2 pump P501 starts for the first […]
Operation of Hot Water System-700L Supercritical CO2 Extractors
Operation of Hot Water System Mainly refers to the process of starting the heating boiler (or steam), heating the water in the hot water storage tank C304, and then starting the hot water circulation pump, using water as a heat source to heat the extraction kettle and other equipment. a) The participating hot water system […]
Operation of Cold Water System-Supercritical Fluid Extraction System
Operation of Cold Water System It mainly refer to the process of starting the water-cooling unit E406 and cooling the CO2 in the condenser E401 and the intermediate storage tank C302 with cooling water. a) The equipment involved in the refrigeration system is: 1) water cooling unit E406; 2) cooling water motor P604; 3) cooling […]
Routine Examination before Opening of the Extraction System
Operation Procedure Introduction to the operation of main equipment of this plant will be made first in this chapter, and then to the extraction recycle. Routine Examination before Opening of the Extraction System Examine if the electrical equipment has good ground connection, if electrical voltage meets the requirement and if the working environment is safe. […]
Pressure Transmitters-700L Supercritical Fluid Extraction Part
Pressure Transmitters The pressure transmitters are elements for detecting and control system pressure. There are 15 pieces (PRC-01~PRC-15) . Siemens DS III HART series, which consists sensor unit, in-place button with magnetic induction, and EPROM electronic modular. Sensor unit consists of pressure sensor and temperature sensor, with which it fully compensates the static characteristics and […]
Temperature Sensors-700L Supercritical Fluid Extraction Part
Temperature Sensors The temperature sensors are the elements for detecting and control system temperature and there are 13 pieces (PRC-01~TRC-15). They detect the temperature at various temperature control points and feedback to PLC control system. PLC control system then will transmit and control the opening and closing of each pneumatic ball valves to fulfil the […]
Pneumatic Double-acting Ball Valves-700L Industrial Supercritical CO2 Extraction Machine
Pneumatic Double-acting Ball Valves The pneumatic double-acting ball valves, the main actuator to regulate the water temperature, have five pieces (M05~M08). They can automatically regulate the water temperature of the water jackets of various devices for good temperature control. Tags: Pneumatic Double-acting Ball Valves, CBD Extraction CO2 Industrial, Cannabis CBD Extraction Distillation, Industrial Supercritical CO2 […]
Regulating Valves-700L Supercritical Fluid Extraction Fruit
Regulating Valves The regulating valves are the main actuator to regulate the pressure of piping. There are 4 pieces (K01~K04) with high-pressure valve and pneumatically operated diaphragm actuator. The pressure change of the compressed air will change the position of the membrane on the film cylinder, and then the regulating valve adjusts the opening angle […]
The Quick Opening Mechanism-700L Supercritical CO2 Extraction System
The Quick Opening Mechanism The quick opening mechanism is an electrical, pneumatical and mechanical integrity structure (as shown in Fig 3.11) consisting of a cylinder (clamp, lift and bolt) , a slide rail, a bracket and a pneumatical system. Pneumatical system provides clean air source and adjust the air flow through a speed adjusting joint […]